The flow and heat transfer inside HP compressor rotating cavities are buoyancy driven and are known to be extremely difficult to predict. The experimental data of Laser-Doppler Anemometry (LDA) measurements inside an engine representative cavity rig is presented in this paper. Traverses using a two component LDA system have been carried out in the shaft bore and the cavity regions in order to map the axial and tangential velocity components. The velocity data is collected for a range of Rossby, Rotational and Axial Reynolds numbers, Ro, Re? and Rez : 0.08